Maintenance-Free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery for Electric Power

Products

HomeHome / Products / AGM Battery / Details
Maintenance-Free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery for Electric Power

Maintenance-Free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery for Electric Power

Maintenance-free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery Battery connectionOnly batteries or bat

Send your inquiry

DESCRIPTION

Basic Info
Model NO. KPT150-12
Installation Packaged
Rechargeable Chargeable
Approx Weight 40kg
Unit/Carton 1
Carton Dimension 496*183*273mm
Transport Package Carton/ Pallet
Specification 483*170*239mm
Trademark kptgu
Origin China
Production Capacity 600 PCS/Day
Product Description
Maintenance-free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery
Specification Type
Model NO.VoltsCapacity(AH)Approx Dimension(mm)Approx Weight(kg)Unit/carton(pcs)Carton Dimension(mm)
20hrs rateLWH
KPT7-1212715165952.110353*320*130
KPT12-12121215199953.68415*315*120
KPT17-1212171817616764365*179*210
KPT24-12122416512517582263*176*198
KPT33-12123819513015592275*208*202
KPT38-121238197166171122345*205*210
KPT55-121240230138207151235*145*235
KPT65-121265350166174201365*179*210
KPT70-121270260168210211270*178*245
KPT100-1212100329172216291350*186*265
KPT120-1212120406173237331420*186*270
KPT150-1212150483170239421496*183*273
KPT200-1212200522239218601535*253*278

Maintenance-Free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery for Electric Power

Battery connectionOnly batteries or battery packs with the same actual capacity can be used in series.The connection part shall be tight to prevent sparks; in case of poor contact, the contact surtace can be cleaned with soda water.Only batteries or battery groups with the same actual voltage can be used in parallel,The positive and negative poles shall not be reversed or short circuited.The batteries of the battery pack shall be separated by more than 10 mm to facllitate heat dissipation.Battery chargingFloating charge (limit voltage, control current) use: charging voltage2.20-2.30V single cell (25 C).When trickle current is used, the floating charge current of the battery is adjusted to less than 2mAl ah;Temperature compensation, the temperature compensation coefficient of each monomer is 3MV c.(based on20 'ºC)Cyclic use (stop when fully charged, charge when fully discharged):charging voltage 2.35-2.45V single call maximum power.The flow shall not be greater than 25%of the nominal capacity;Note:the battery shall not be used in closed or high temperatdre environment, and shall be kept away from the fire source.Storage and installation1.For batteries not put into use, the connecting wire shall be removed, the pole sheath shall be covered and wiped clean;2.Maintain and charge the battery every three months. T he charging method is limited current and constant voltageMethod: the initial charging current is 0.1CA, and the charging volltage is 24V single cell (at 25 c);3.The battery shall be stored in a dry and ventilated place, away from direct sunlight and heat source.4.When handling the battery, the force shall be even, and the stress part is the shell artof the batfery to avoid damaging the pole;5.Insulating tools shall be used during installation to prevent electric shock.Points to note
1.When the batlery is discharged from the factory. do not attempt to disassemble the battery to avoid danger .if the battery shells damaged accidentally ln case of contact with sulfuric acid, please wash with plenty of clear water immediately, and see a doctor immediatly if necessary2.Do not mix the old and new batteries;3.Do not use battery in sealed container;4.The battery shall have a complete resume , including factory date, installation date, operation record, etc;5.Regularly (once a year) check whether the connecting wire is loose. lf it is loose, fasten it;6.Wipe the battery regularly (once every three months) with soft fabric to keep the battery clean;7.Do not use organic solvents to clean the battery.8.Pay attention to the battery spacing to prevent salt bridge.

Maintenance-Free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery for Electric Power

MORE PRODUCTS:KPT-38-12 KPT-65-12 KPT-100-12 KPT-120-12 KPT-150-12 KPT-200-12

Maintenance-Free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery for Electric Power

Our company offers variety of products which can meet your multifarious demands. We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers.Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.

Maintenance-Free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery for Electric Power

Maintenance-Free AGM Battery UPS Battery Solar Valve-Regulated Lead Acid Battery for Electric Power